Cookie Img
Back to top
Offering wide range of Boilers, Industrial Boilers, Steam Boilers, Hot Water Generator, Hot Water Boiler, Thermic Fluid Heater, etc....

Beginning & Success

BALKRISHNA BOILERS PVT. LTD. has been established as a prominent manufacturer and supplier of different sorts of heating system, drying frameworks, boilers, commercial boilers, industrial boilers, steam boilers and their extra parts throughout the previous 20 years. Our warming frameworks like Steam Boilers accompany the bleeding edge innovation with higher productivity, less upkeep and easy to use highlights. The organization has the capacity supply application-supporting items with complete specialized move down on all perspectives including building, configuration and establishment of Wood Steam Boilers. To locate the most values in the venture for Heating Devices and Machines, one can believe a certify name of the business with the evidence of achievement more than two decades. The organization has an across the board system being overseen through different deals groups, encouraging it to convey heating systems all over the world.

Quality Policy & Its Strategies

With all inclusive and comprehensive inspection and wide testing regimen that go a long way towards assuring of products integrity and client credibility in its products, Balkrishna Boilers Pvt. Ltd., follows the mechanism of controlling overall quality of all products, complying with the globally accepted standards in terms of design and performance. It consistently implements the policy of ongoing quality enhancement of Industrial Boilers. We have been engaged in enhancing scientific research and advancing manufacturing techniques in order to engineer greater-efficiency Steam Boilers, Industrial Boilers which ensure better outcomes, expected quality, reliable performance and cutting-edge design.  

Home » Products » Thermic Fluid Heater » Gas Fired Thermic Fluid Heater

Gas Fired Thermic Fluid Heater

Gas Fired Thermic Fluid Heater
Gas Fired Thermic Fluid Heater
Product Code : 19
Product Description

We are acknowledged by our clients as the reckoned entity, engaged in manufacturing and exporting Gas Fired Thermic Fluid Heater. We manufacture this heater at our modern production unit using high quality materials in compliance with the quality standards set by the industry. Our heater is demanded by the industries for ensuring optimum heat transfer. We are offering this Gas Fired Thermic Fluid Heater to our clients at a competitive price. 

Features:

  • Easy to operate
  • Minimum maintenance  
  • High fuel efficiency

Further Details 

Technical Specification
CAPACITY
1,00,000 Kcal/Hr TO 50,00,000 KcaL/Hr
TEMPERATURE Up to 350° C
FUEL
L.D.O./GAS / DESSEL
FIRING MODE AUTOMETIC BURNER FIRED SYSTEMS
FURNACE
INTERNAL FURNACE

Technical Specifications:

DESCRIPTION

UNITS

DP-0400

DP-0600

DP-1000

DP-1500

DP-2000

DP-2500

DP-4000

DP-4500

Capacity

Kcal/ hr

400000

6,00,000

1,000,000

1,500,000

2,000,000

2,500,000

4,000,000

4,500,000

Max. Outlet temperature SS

Deg C

280

Des Flow O thermic Fluid

M3/h

20

30

50

80

100

125

240

250

Max. Head Available At Heater Outlet

mIc/bar

20/1.45

Thermic Fluid Temperature Riss S

Deg C

40

40

40

40

40

40

33

36



Fuel Firing Parameter

Fuel Consumption-Hsd

Kg/h

44.30

66.45

110.74

166.11

221.48

276.85

435.7

490.2

LDO

Kg/h

45.60

68.40

114.00

171.00

228.00

285.00

461.4

519.0

FO

Kg/h

48.320

72.30

120.50

180.75

240.99

301.24



Natural Gas

Nm3/h

55.36

83.04

138.41

207.61

276.82

346.02

553.6

622.8

LPG

Nm3/h

18.87

28.30

47.17

70.76

94.34

117.93

188.7

212.3

Fuel NCV - HSD

Kcal/h

10,500.00

LDO

Kcal/h

10,200.00

FO

Kcal/h

9,650.00

Natural Gas

Kcal/nm3

8,500.00

LPG

Kcal/nm3

24,940.00

Thermal Efficiency -Ido/hsd

% on NCV

86+/-2

FO

% on NCV

86+/-2

Natural Gas / Lpg

% on NCV

85+/-2

Burner Control


Single / Two Stage 33-100% Stepless

Electrical Connected Load


Electric Supply- 415 or 380 Volt AC+/6%Hz+/-3%,3 Phase

Burner motor

kW

0.75

1.50

4.0

5.5

7.5

5.5

18.5

21.7

Fuel Pump motor

kW

Part of Burner

Oil Preheater (inbuilt in burner)

kW

3.0

3.0

6.0

12.0

12.0

12.0



Thermic Fluid Circulation Pump Motor

kW

5.5

11.0

11.0

11.0

15.0

15.0

45

55

Total (incl control panel )- Hsd/Iod

kW

6.75

13.0

21.5

29.0

35

33.0

64.5

77.7

NG/LPG

kW

6.8

13.0

15.5

29.0

35.0

33.0

64.5

77.7

FO

kW

9.75

16

21.5

29.0

35.0

33.0

64.0

77.2

Dimensions



Length/height

metres

2.66

2.96

3.16

3.86

4.31

4.71

75

8.5

Diameter

metres

1.59

1.62

1.90

2.17

2.40

2.64



Type of Heater Installation


Vertical of Horizontal

Main unit Weight (dry =) (w/o Burner)

kg

2200

3000

4200

5800

7700

10500

16000

19000

De tank weight (dry)

kg

300

300

450

570

770

910



Volumetric Capacity Of D/e tank

liters

500

500

1000

1500

2000

3000



Volumetric Of Coll

liters

318

360

675

1250

1600

2040

4000